A bathroom is the most tightly regulated room in a house electrically, and for good reason. This is not an area for improvisation.

The zones

The wiring regulations divide a bathroom into zones based on proximity to water, and each has requirements for the equipment installed in it.

Zone 0: the inside of the bath or shower tray. Only very low voltage equipment specifically rated for immersion may be installed here.

Zone 1: the area directly above the bath or shower tray, up to 2.25m above the floor. Equipment needs a suitable ingress protection rating, commonly IPX4 as a minimum.

Zone 2: extends 0.6m horizontally beyond zone 1, and to the same height. Similar protection requirements apply.

Outside the zones: the rest of the room, where requirements are less restrictive, though other rules still apply.

Where a shower is fitted without a tray, the zone is measured from the shower head position.

IP ratings

An IP rating has two digits: the first for solid objects, the second for water.

The second digit matters in a bathroom. IPX4 means protected against splashing water from any direction; IPX7 means protected against immersion.

Fittings sold for bathroom use state their rating, and it must be appropriate for the zone.

Sockets

Socket outlets are not permitted within 3m of the zone 1 boundary.

In most domestic bathrooms this means no sockets at all.

The exception is a shaver supply unit to the relevant standard, which contains an isolating transformer and may be fitted outside zones 0, 1 and 2.

This is why people run hairdryers from the landing, and why an extension lead into a bathroom is a genuinely dangerous idea.

RCD protection and bonding

All circuits serving a bathroom require RCD protection.

Supplementary equipotential bonding of metal pipework and fittings may be required, depending on whether certain conditions are met in the wider installation.

Whether it is needed is a judgement for a qualified electrician based on testing the installation, not something to assume either way.

Switches

Ordinary wall switches are not permitted within the zones.

Lighting and fans in a bathroom are normally operated by a ceiling-mounted pull cord switch, or by a switch located outside the room.

Notifiable work

Electrical work in a bathroom is notifiable under the building regulations in England and Wales, because a bathroom is a special location.

That means it must be carried out by a registered competent person who can self-certify, or notified to building control in advance and inspected.

This applies to adding a light, a fan, a shaver socket, a heated towel rail or an electric shower.

Scotland and Northern Ireland have their own arrangements, so check locally.

The practical consequence is that bathroom electrics is a job for a registered electrician.

Common items and where they go

Downlights above a bath or shower need an appropriate IP rating and, where in zone 1, must be suitable for that zone.

Extractor fans mounted in zone 1 need the appropriate rating, and many are low voltage for that reason.

Electric showers need a dedicated circuit, RCD protection and a pull cord isolator, and are firmly a job for an electrician.

Heated towel rails that are electric need a connection outside the zones or a suitably rated fitting.

Mirrors with lights and demisters state a zone rating; check it against where you intend to fit it.

What you can reasonably do

Plan the positions and mark them on the wall.

Chase walls and run cable for an electrician to connect and test.

Do the making good afterwards.

Get the certificate when the work is finished and keep it, since it will be asked for when you sell.

Why the rules are strict

Wet skin has far lower electrical resistance than dry skin, and a bathroom contains earthed metal pipework and fittings that a person is in contact with.

The combination is what makes a fault that would be a shock elsewhere potentially fatal here.

That is the reasoning behind the zones, the ingress protection ratings and the ban on socket outlets.

Existing installations

Older bathrooms frequently contain fittings that would not be permitted today, including unrated light fittings and, occasionally, sockets.

These are not automatically unlawful, since installations are assessed against the standards of their time.

They are worth having assessed by an electrician, and any socket in a bathroom should be removed.