A wet room is a bathroom where the floor itself is the shower area, draining to a gully, with no tray and often no enclosure. It looks superb and is considerably more demanding to build than a conventional shower.
What it requires
Complete waterproofing of the floor and the lower walls, and full height in the shower area, with no gaps.
Falls to the drain across the wet area, so water runs to the gully rather than across the room.
A drainage point with adequate capacity, and access to it for cleaning.
Structural provision for the drain and the falls, particularly on a timber floor.
Good ventilation, since the whole room becomes wet.
Every one of these must be right. There is no margin in a wet room, because a failure floods the structure rather than a tray.
Creating the fall
Floor formers are the usual approach. These are rigid pre-sloped panels, cut into the floor or laid over it, with the gully already positioned.
They give a consistent gradient and remove the guesswork.
The alternative is forming falls in screed, which is skilled work.
The fall must be enough to move water, typically in the region of 1 in 50 to 1 in 80 depending on the system, and consistent across the whole wet area.
Water finds a level surface and sits there, so a fall that is nearly right is not right.
Timber floors
The former and the gully both need depth, which means cutting into the floor structure.
Notching or cutting joists is structural work and there are strict limits on where and how deep. Get proper advice rather than cutting what is in the way.
Trimming around a gully may need additional joists or a structural design.
The floor must also be rigid, since any deflection cracks the waterproofing and the tiles.
Overboard with plywood or a suitable board before the former goes in.
Solid floors
Easier in some ways, and the drain still needs a route to the waste with a fall.
On a ground floor slab this may mean cutting the concrete, which is a substantial job.
Check the position of the existing drainage before committing to a wet room on a solid floor.
Tanking
The whole floor and the lower walls must be waterproofed as a continuous membrane, with no break at any junction.
Use a single manufacturer's system throughout, following their instructions exactly.
Tape every junction: wall to wall, wall to floor, around the gully, around every pipe penetration.
The membrane must be bonded to the gully flange, which is what makes the connection watertight.
Take the wall waterproofing to full height in the shower area and to a sensible height elsewhere.
Test the waterproofing before tiling where the system allows, by blocking the gully and flooding the floor.
Drainage
The gully must have the flow rate to take the shower output, which is stated by the manufacturer.
A linear channel drain against a wall handles more flow and can be neater than a centre gully.
The trap must be accessible for cleaning, since hair blocks wet room drains constantly.
Practicalities
Water travels further than people expect. A screen or a partial glass panel keeps the rest of the room drier without enclosing it.
Everything in the room gets damp, including toilet roll and towels. Position them accordingly.
Underfloor heating is close to essential, both for comfort and to dry the floor.
Slip resistance matters more than in a normal bathroom, so choose a suitably rated tile.
Is it the right choice
Excellent for accessibility, for awkward-shaped rooms, and for a small en-suite where a tray would not fit.
More expensive and less forgiving than a shower tray, and a poor choice as a first tiling project.
For most bathrooms, a low-profile tray properly tanked gives a similar appearance with far less risk.
Who should build one
A wet room is a job where the consequences of a mistake are severe and hidden.
The tanking and the falls are the parts to be most cautious about, and many capable DIYers do the strip-out, the second fix and the decorating and pay someone to form and waterproof the floor.
Whoever does it, use a complete proprietary system and follow its instructions exactly.