Hanging a door is a genuinely satisfying job and one where a millimetre matters. Almost nothing about an existing opening will be square, plumb or parallel.
Standard sizes
The common British internal door is 1981 by 762mm and 35mm thick, which is the old six foot six by two foot six.
Other standard widths are 686mm and 838mm, with 610mm for cupboards.
Metric doors at 2040 by 826mm are used in newer houses.
Measure the existing door and the opening before ordering, since older houses frequently have non-standard openings.
Measure the opening properly
Measure the width at top, middle and bottom.
Measure the height at both sides and the centre.
Check both jambs for plumb with a spirit level, and the head for level.
Measure the diagonals. If they differ, the opening is out of square, and the door will need tapering to suit.
Buy a door that is slightly larger than the opening in both directions, so there is material to trim.
Clearances
These are what stop a door binding or rattling.
Around 2 to 3mm at the top and both sides. A useful check is that a two pound coin, or a pencil, fits the gap consistently.
Around 6 to 10mm at the bottom over a hard floor, and more over carpet. Measure the carpet and underlay thickness before deciding.
Where the door must clear a threshold or a change of level, check that too.
Consistent gaps matter more than exact figures. A gap that varies down the side is what looks wrong.
Trimming to fit
Work on one edge at a time and check the fit repeatedly.
Take the bulk off the hinge side, since that edge is hidden and the latch side needs to keep its lock block.
Where a lot must come off, split it between both edges so the stiles stay balanced in appearance.
Do not exceed the manufacturer's maximum trim, which is stated for engineered and hollow-core doors and is typically only a few millimetres each edge.
Plane the latch edge with a slight bevel, around 2 to 3 degrees, leaning away from the stop, so the leading edge clears as the door swings closed.
Hinge positions
The convention that works.
Top hinge: around 150mm from the top of the door.
Bottom hinge: around 225mm from the bottom.
Third hinge: centred between them, or slightly above centre.
Two hinges are adequate for a light internal door; three is better and is normal for heavier doors, and required for fire doors.
Where you are replacing a door in an existing lining, mark the hinge positions from the lining rather than the old door.
The order of work
Trim the door to fit the opening with the correct clearances, using wedges to hold it in position while you check.
Mark the hinge positions on the door and the lining together, with the door wedged in the opening.
Cut the hinge recesses.
Fix the hinges to the door first, then offer the door up and fix into the lining.
Fit one screw per hinge initially, check the swing, then fit the rest.
Fit the latch and handle last.
Holding a door on your own
Doors are heavy and awkward to hold at the right height.
Use wedges under the bottom edge to raise it to the exact position, or a door lifter, which is a simple foot-operated lever.
A pair of thin packers at the top and sides holds the clearances while you mark.
Checking it works
The door should swing freely and stay where it is put, without drifting open or closed.
Drifting indicates the lining is out of plumb or the hinges are not aligned.
Check the gaps are consistent all round and that the face sits flush with the stop.
Handing
Decide which way the door opens before hanging it.
A door normally opens into the room, against a wall rather than into the space, and should not swing into a light switch, a radiator or another door.
In a small room, consider whether it would be better rehung the other way or changed for a sliding door.
Finishing
Prime and paint or finish all six faces, including the top and bottom edges, before hanging where possible.
Unfinished edges absorb moisture and cause the door to swell and stick, which is why a door that fitted in summer catches in winter.