Boarding a loft looks like the simplest job in the house and is one of the easiest to get badly wrong, in two separate ways.
Problem one: the insulation
Loft insulation works by trapping air. Compressing it destroys most of its value.
Current recommended depth is around 270 to 300mm of mineral wool, which is far deeper than a standard ceiling joist.
Boarding straight onto the joists squashes that insulation to around 100mm, losing a large part of its performance across the whole boarded area.
Worse, the boarded area becomes a cold bridge, and the underside of the boards is a cold surface with warm moist air from the house reaching it. That causes condensation, damp boards and mould.
The solution: raise the boards
Use a proprietary loft leg or raised boarding system.
These plastic or timber supports sit on the joists and raise the boarding above the full depth of insulation, leaving an air gap.
The insulation stays uncompressed, the ventilation path is maintained, and the boards stay warmer and drier.
Fit the legs to the joists, lay the insulation to full depth between and over the joists, and board on top.
This costs more than boarding directly and is the correct way to do it.
Problem two: the weight
Ceiling joists in most houses are sized to hold up a ceiling, not to carry a floor.
They are frequently 100mm deep or less, spanning further than a floor joist would, and in a trussed roof they are part of a structural truss designed as a whole.
Loading them with boxes, books and equipment can cause ceilings to crack and sag, and in a trussed roof it can affect the truss.
Never cut, notch or remove any part of a roof truss, including the diagonal bracing. Trusses are engineered as a system and cutting one is structural work.
Keep loads light and distributed, near the supported edges rather than mid-span, and treat a loft as light storage only.
Where you want genuine floored storage, or anything approaching a room, the floor needs designing and strengthening, and a habitable loft conversion is a building regulations matter entirely.
Ventilation
A cold loft relies on ventilation to remove moisture that rises from the house.
Do not block the eaves ventilation by pushing insulation or boards tight into the eaves.
Maintain a clear air path at the eaves, using rafter vents or ventilation trays where insulation is deep.
Make sure any bathroom or kitchen extractor duct passing through the loft is insulated and discharges outside, never into the loft.
Check the loft hatch is draughtproofed and insulated, since it is a major route for warm moist air.
Practical points
Do not board over recessed downlights or cover them with insulation unless they are rated for it, since they need clearance and can overheat. Use fire-rated fittings with proper covers.
Keep insulation clear of any heat-producing equipment.
Do not bury cables in insulation where it can be avoided, since cables carry less current when insulated.
Leave access to the water tank, the cistern and any electrical junction.
Board a defined area rather than the whole loft, which uses less material and leaves the rest of the insulation undisturbed.
Working safely up there
Never step between the joists. A ceiling will not carry your weight and falls through ceilings are common and serious.
Use crawl boards to spread your weight until the boarding is down.
Take a light. Lofts are dark and full of trip hazards.
Wear a mask and gloves handling mineral wool, which irritates skin and airways.
Older insulation and lagging may contain asbestos, particularly loose fill and pipe lagging in pre-2000 properties. Do not disturb anything unidentified.
Work with someone else in the house, and tell them you are going up.
What to store up there
Light, dry, rarely used items: seasonal decorations, luggage, camping equipment.
Not books, tools, paint or anything heavy, and not anything that matters if it gets damp.
Use plastic boxes rather than cardboard, and keep them off the insulation.
Before you start
Check the joist depth and spacing, and look for signs of an existing problem: sagging ceilings, cracks, or a trussed roof.
Work out how much insulation is there now and how much more is needed to reach current depth.
Decide the area to board and mark it out before buying anything.