Timber Connectors and Joist Hangers

Timber Connectors and Joist Hangers
DIY Guides Editorial 19 May 2026

Joist hangers, framing anchors and restraint straps are structural components. They are designed and tested as a system, and they only perform if fitted exactly as intended.

The types

Joist hanger. A pressed steel shoe supporting the end of a joist against a wall, a beam or another joist. Available for masonry, for timber to timber, and in various depths and widths.

Framing anchor. An angled bracket connecting two timbers at a junction, transferring load where nails alone would be inadequate.

Restraint strap. A long flat strap tying a wall to a floor or a roof structure, preventing the wall moving away. Frequently specified in extensions and conversions.

Truss clip. Fixing a roof truss to the wall plate, resisting wind uplift.

Post base and post anchor. Holding a post above ground level, which greatly extends its life.

Timber connector plate, nail plate. A flat plate with punched holes joining two timbers face to face.

Angle bracket and gusset. Reinforcing a corner or a junction.

The rule that governs everything

Use the specified nails, in every hole.

  • Connectors are tested with a particular fastener in a particular pattern
  • Every hole is there because the calculation requires it
  • Leaving holes empty reduces the capacity proportionally, and there is no way for anyone to know afterwards how many were filled
  • The correct fastener is normally a sherardised or galvanised square twist nail, sized for the connector
  • Some connectors are approved for specific structural screws; check the manufacturer's data before substituting

Do not substitute ordinary woodscrews, and never drywall screws. Drywall screws are hardened and brittle, and they snap under shear load. They have no place in a structural connection.

Step 1: fitting a joist hanger to timber

  1. Choose a hanger matching the exact joist size. A hanger too wide lets the joist move; too narrow will not accept it
  2. Mark the position so the joist top is flush with the supporting member, or at the level required
  3. Hold the hanger tight against the supporting timber with no gap behind the back plate
  4. Fix through every hole in the back plate with the specified nails
  5. Drop the joist in, and check it is fully seated on the bottom of the hanger. A joist not bearing on the seat transfers its load to the nails alone
  6. Fix through every hole in the side flanges into the joist
  7. Check the joist is level and correctly bearing before nailing

Step 2: fitting a hanger to masonry

  • A masonry hanger has a long back plate built into the wall as it is constructed
  • Retrofitting into existing masonry usually requires a different type, fixed with specified anchors
  • The wall must be capable of carrying the load, which is a structural question
  • Building a hanger into new work requires the courses above to be laid on it

Step 3: the common mistakes

  • Not filling every hole. By far the commonest, and it directly reduces capacity
  • Using the wrong fastener. Ordinary screws, drywall screws, or nails that are too short or too thin
  • A gap behind the hanger, so it is not bearing properly against the support
  • The joist not fully seated on the bottom of the hanger
  • Wrong size hanger for the joist
  • Notching or drilling the joist near the hanger, which weakens it exactly where the load is concentrated
  • Fixing into the end grain of the supporting member
  • Bending or modifying the connector to make it fit

Never cut, bend, drill or modify a structural connector. If it does not fit, it is the wrong one.

Step 4: corrosion

  • Connectors and their nails must match the environment
  • Galvanised or sherardised for internal dry use
  • Stainless for external, damp, or in contact with treated timber
  • Modern treated timber corrodes zinc coatings, so check the connector is rated for use with it, or use stainless
  • Oak and cedar corrode steel and stain black. Use stainless connectors and nails
  • Never mix stainless connectors with galvanised nails, or the reverse

Step 5: notching and drilling joists

Relevant because services frequently need to pass through.

  • Joists are strongest at the top and bottom edges, so cutting there does the most damage
  • Notches in the top edge are permitted only within defined zones and depths
  • Holes must be drilled on the neutral axis, at the centre of the depth, within defined zones and diameters
  • Never notch or drill near a bearing point, such as at a hanger or over a wall
  • The permitted zones and sizes are set out in the Building Regulations guidance and in TRADA publications
  • Where in doubt, ask a structural engineer. A badly notched joist is a real structural defect

Step 6: when this is notifiable

Structural work is generally notifiable under Building Regulations.

  • Forming or altering openings in structure
  • Removing or altering loadbearing walls
  • Altering floor or roof structure
  • Loft conversions and extensions

Where connectors are specified on a structural drawing, they are specified for a reason and must be fitted exactly as drawn. Building control will inspect them.

Keep the paperwork. A completion certificate will be asked for when you sell.

Step 7: buying

  • Buy connectors and their nails together, from the same manufacturer
  • Check the manufacturer's load tables where the load matters
  • Note the connector reference so it can be matched later
  • Buy plenty of nails: a single hanger takes a surprising number, and running out mid-job is a temptation to leave holes empty
  • Check the coating is right for the situation

If it goes wrong

Hanger too wide for the joist: use the correct size. Packing it out is not acceptable.

Joist not seating fully: the hanger is in the wrong position, or the joist end is not square.

Ran out of the correct nails: stop and get more. Do not fill the remaining holes with something else.

Existing hangers with empty holes: fill them with the correct nails if you can access them.

Unsure whether it is structural: ask a structural engineer or building control.