Membranes and Waterproofing

Membranes and Waterproofing
DIY Guides Editorial 2 June 2026

Membranes control where water and water vapour go. They are cheap, hidden, and getting them wrong causes expensive damage years later.

The four jobs

Damp proof course, DPC. A horizontal barrier in a wall stopping moisture rising from the ground.

Damp proof membrane, DPM. A barrier under or within a floor stopping moisture rising from the ground.

Breather membrane. Keeps liquid water out while letting water vapour through. Used on the cold side of a construction.

Vapour control layer, VCL. Stops water vapour getting into a construction. Used on the warm side.

The distinction between the last two is the one that matters, and confusing them causes rot.

Damp proof course

  • Usually a polymer strip, visible as a black line in the mortar joint
  • At least 150mm above finished ground level
  • Older buildings may use slate, engineering brick, or have no DPC at all
  • Also needed vertically at openings and around door and window reveals
  • A cavity tray directs water out of the cavity above openings and abutments

Bridging is the commonest cause of rising damp in practice.

  • Raised ground levels: a new path, patio, drive or flower bed above the DPC line
  • Render carried down across the DPC
  • Debris in the cavity forming a bridge
  • An abutting structure such as a porch or a lean-to
  • Soil, mulch or plants piled against the wall

Before assuming a DPC has failed, check whether it has been bridged. Lowering a path is far cheaper than injecting a wall, and frequently it is the actual problem.

Damp proof membrane

  • Heavy gauge polythene, typically 1200 gauge, beneath a floor slab or between slab and screed
  • Must be continuous and lapped generously, with laps taped
  • Must connect to the DPC in the walls, so there is an unbroken barrier. A gap between the two is a direct route for moisture
  • Protect it from puncture during construction; a hole is a leak
  • Liquid applied DPM systems are used on existing floors
  • Never lay an impermeable floor covering over a floor without a DPM, which traps moisture and causes the covering to lift

Breather membrane

  • Vapour permeable and water resistant. Water cannot get in; vapour can get out
  • Used on the outside of timber frame walls under cladding, and under roof tiles as a sarking layer
  • Allows any moisture in the structure to escape outward
  • Fit on the cold side, outside the insulation
  • Lap correctly, working from bottom upward so water sheds over each lap
  • Some roofing underlays are vapour permeable and some are not; fitting an impermeable underlay without adequate ventilation causes loft condensation

Vapour control layer

  • Polythene sheet, foil-faced board, or a proprietary membrane
  • Always on the warm side of the insulation, which means the inside in a UK climate
  • Stops warm moist internal air reaching the cold zone within the structure and condensing there
  • Must be continuous and sealed at every lap, edge and penetration: cables, pipes, sockets, downlights
  • A gap concentrates moisture at that point rather than distributing it

The rule: vapour control on the warm side, breather membrane on the cold side. Reversing them traps moisture inside the construction, where it condenses and rots timber invisibly.

Tanking

Waterproofing a structure below ground: a cellar, a basement, a retaining wall.

  • Cementitious tanking slurry: painted or trowelled on, bonding to the substrate. Suitable for sound masonry
  • Cavity drain membrane: a studded plastic membrane holding water away from the finish and directing it to a drainage channel and a sump. Manages water rather than resisting it, which is generally more reliable in a basement
  • Liquid applied and sheet systems for external tanking

Tanking a cellar is specialist work. Water under hydrostatic pressure finds any weakness, and a failed system is very difficult to put right once the space is finished. Take professional advice and use a specialist with an insurance-backed guarantee.

Wet area waterproofing

  • Tanking kits for showers and wet rooms: a liquid membrane with reinforcing tape at corners and junctions
  • Tile backer board is waterproof through its thickness, unlike moisture resistant plasterboard
  • Tiles and grout are not waterproof. Water passes through grout, so the waterproofing must be behind the tiles
  • Pay particular attention to corners, junctions, and around pipe penetrations, which is where failures start
  • Moisture resistant plasterboard is water resistant, not waterproof, and is not adequate inside a shower enclosure

Step 1: installing membranes well

  1. Continuity is everything. A membrane with a gap is not a barrier
  2. Lap generously, typically 100 to 150mm, and follow the manufacturer's figure
  3. Tape or seal every lap with the tape specified for that product
  4. Seal around every penetration: pipes, cables, fixings
  5. Lap in the direction water will run, so it sheds over rather than into
  6. Protect from damage during subsequent work
  7. Photograph it before covering it up

Step 2: junctions

Almost every failure is at a junction, not in the middle of a sheet.

  • Wall to floor, where DPC must meet DPM
  • At openings, where cavity trays and vertical DPCs are needed
  • At abutments where a structure meets an existing wall
  • Around penetrations
  • At changes of level
  • Take extra care and extra material at every junction

Step 3: ventilation still matters

  • Membranes control where moisture goes; ventilation removes it
  • Do not block eaves ventilation when insulating a roof
  • Do not block underfloor air bricks, which keep joists dry
  • Maintain a ventilated gap where the construction requires one
  • A sealed construction with no ventilation route is a construction that cannot dry

Step 4: older buildings

  • Pre-1919 solid wall buildings generally have no DPC and were not designed to have one
  • They manage moisture by allowing it through and evaporating it, using lime mortar and lime plaster
  • Applying impermeable membranes, cement render or gypsum plaster traps moisture and drives it elsewhere, frequently making things worse
  • Use breathable materials, and address the source: rainwater goods, ground levels, ventilation
  • Take advice from someone experienced with traditional construction

If it goes wrong

Damp at the base of a wall: check for a bridged DPC before anything else.

Condensation in a loft: ventilation blocked, or an impermeable underlay without adequate ventilation.

Floor covering lifting: moisture through a floor with no DPM.

Rot in insulated roof timbers: the vapour control layer was missing, incomplete, or on the wrong side.

Water through a tiled shower wall: tiles and grout are not waterproof. The wall needed tanking behind them.