Most household work is accurate to a millimetre. Some is not: matching a fitting, a bearing, a drill size or a thread needs finer measurement than a tape can give.
When you need it
- Identifying a pipe, a bolt or a thread size
- Matching a bearing, a seal or an O-ring
- Measuring a drill bit or a cutter
- Checking sheet or plate thickness
- Matching a replacement part
- Measuring a euro cylinder
- Setting a machine or a jig
- Checking a gap or a clearance
Callipers
A sliding jaw on a scale, measuring far more precisely than a rule.
Digital calliper. An electronic display, typically reading to 0.01mm. Switches between metric and imperial, and can be zeroed anywhere. The sensible choice for most people: no reading skill required, inexpensive, and accurate enough for anything domestic.
Vernier calliper. A main scale and a sliding vernier scale. No battery, extremely durable, and it requires learning to read.
Dial calliper. A dial gauge driven by a rack. Easy to read, no battery, and vulnerable to grit in the rack.
What a calliper measures
Four measurements from one tool, which is why it is so useful.
- External: the large lower jaws, closing on the outside of an object
- Internal: the small upper jaws, opening inside a bore or a slot
- Depth: the rod extending from the end as the jaws open
- Step: the flat face at the end of the main beam against the sliding jaw
Step 1: use a calliper
- Wipe the jaws and the workpiece clean. A speck of dirt is larger than the tool's accuracy
- Close the jaws fully and check it reads zero. Zero a digital calliper here
- Open the jaws and place them over the work
- Close gently using the thumbwheel, with light consistent pressure
- Do not force the jaws; over-squeezing gives a small reading and damages the tool
- Hold the work square in the jaws, seated fully
- Use the locking screw to hold the reading if needed
- Read the display
- Measure two or three times, and at different points, since components are rarely perfectly round or parallel
Step 2: reading a vernier
For a metric vernier reading to 0.02mm.
- Read the main scale at the zero mark of the vernier scale, taking the last whole millimetre passed
- Look along the vernier scale for the one graduation that lines up exactly with a main scale line
- That vernier graduation gives the decimal part
- Add the two together
Example: the vernier zero sits just past 24mm on the main scale, and the vernier's 0.36 graduation aligns with a main scale line. The reading is 24.36mm.
Read in good light and directly in line, since parallax is significant at this scale.
Step 3: feeler gauges
A set of thin steel blades in graduated thicknesses, typically 0.05mm to 1mm.
Uses:
- Measuring a gap or a clearance
- Checking a surface against a straight edge to find how far out of flat it is
- Setting a machine clearance
- Measuring how far a workpiece is out of square
- Try a blade in the gap
- The correct blade is the one that fits with a slight drag: it slides but you feel it
- A blade that slips freely is too thin; one that will not enter is too thick
- Blades can be stacked to make up an intermediate thickness
- Wipe clean and oil lightly, since they rust readily
Step 4: micrometers
More precise than a calliper, reading to 0.01mm or better, over a limited range.
- An external micrometer typically covers 0 to 25mm, with larger frames for larger ranges
- Use the ratchet or friction thimble for the final turn, which applies consistent pressure. This is what makes readings repeatable
- Check the zero before use
- Rarely needed for household work, and useful for engineering and restoration
Step 5: common measurements
- Pipe: UK copper and plastic pipe is sized by outside diameter: 10, 15, 22 and 28mm. Measure the outside
- Bolt diameter: measured across the thread crests. M8 is nominally 8mm
- Thread pitch: the distance between adjacent crests. Use a thread pitch gauge, or measure across ten threads and divide
- Spanner size is the distance across the flats, not the bolt diameter. An M8 bolt commonly takes a 13mm spanner
- Drill bits: measure the shank, not the flutes, since the cutting edges may be worn
- Sheet thickness: measure at several points and away from the edge
Step 6: temperature and touch
At this level of precision, small effects matter.
- Metal expands with temperature; a component just off a machine reads larger
- Holding a workpiece warms it
- Let items reach room temperature for precise work
- Handle by the edges where possible
Care
- Keep the jaws and the beam clean. Grit ruins accuracy and wears the sliding surfaces
- Store in the case, not loose in a toolbox
- Do not drop it; a bent jaw is unrecoverable
- Wipe with a lightly oiled cloth
- Remove the battery from a digital calliper for long storage, since it drains and can leak
- Check the zero regularly
- Never use a calliper as a scriber, a screwdriver or a clamp
Cheaper alternatives
- Drill gauge: a plate with graded holes, identifying a drill size instantly
- Thread pitch gauge: leaves matching a thread by shape
- Radius gauge: for internal and external radii
- A steel rule with fine graduations and a magnifier gets closer than you would think
- Take the part to the merchant and match it against stock, which is frequently the fastest answer
If it goes wrong
Reading not repeatable: inconsistent pressure, or dirt on the jaws.
Calliper does not read zero closed: dirt in the jaws, or it needs re-zeroing.
Measurement varies round a component: it is not perfectly round. Take several and note the range.
Part still does not fit: check whether it is a nominal size rather than an actual one.
Digital display erratic: low battery, or moisture in the tool.