DIY Guides Editorial 12 May 2026

Most household work is accurate to a millimetre. Some is not: matching a fitting, a bearing, a drill size or a thread needs finer measurement than a tape can give.

When you need it

  • Identifying a pipe, a bolt or a thread size
  • Matching a bearing, a seal or an O-ring
  • Measuring a drill bit or a cutter
  • Checking sheet or plate thickness
  • Matching a replacement part
  • Measuring a euro cylinder
  • Setting a machine or a jig
  • Checking a gap or a clearance

Callipers

A sliding jaw on a scale, measuring far more precisely than a rule.

Digital calliper. An electronic display, typically reading to 0.01mm. Switches between metric and imperial, and can be zeroed anywhere. The sensible choice for most people: no reading skill required, inexpensive, and accurate enough for anything domestic.

Vernier calliper. A main scale and a sliding vernier scale. No battery, extremely durable, and it requires learning to read.

Dial calliper. A dial gauge driven by a rack. Easy to read, no battery, and vulnerable to grit in the rack.

What a calliper measures

Four measurements from one tool, which is why it is so useful.

  • External: the large lower jaws, closing on the outside of an object
  • Internal: the small upper jaws, opening inside a bore or a slot
  • Depth: the rod extending from the end as the jaws open
  • Step: the flat face at the end of the main beam against the sliding jaw

Step 1: use a calliper

  1. Wipe the jaws and the workpiece clean. A speck of dirt is larger than the tool's accuracy
  2. Close the jaws fully and check it reads zero. Zero a digital calliper here
  3. Open the jaws and place them over the work
  4. Close gently using the thumbwheel, with light consistent pressure
  5. Do not force the jaws; over-squeezing gives a small reading and damages the tool
  6. Hold the work square in the jaws, seated fully
  7. Use the locking screw to hold the reading if needed
  8. Read the display
  9. Measure two or three times, and at different points, since components are rarely perfectly round or parallel

Step 2: reading a vernier

For a metric vernier reading to 0.02mm.

  1. Read the main scale at the zero mark of the vernier scale, taking the last whole millimetre passed
  2. Look along the vernier scale for the one graduation that lines up exactly with a main scale line
  3. That vernier graduation gives the decimal part
  4. Add the two together

Example: the vernier zero sits just past 24mm on the main scale, and the vernier's 0.36 graduation aligns with a main scale line. The reading is 24.36mm.

Read in good light and directly in line, since parallax is significant at this scale.

Step 3: feeler gauges

A set of thin steel blades in graduated thicknesses, typically 0.05mm to 1mm.

Uses:

  • Measuring a gap or a clearance
  • Checking a surface against a straight edge to find how far out of flat it is
  • Setting a machine clearance
  • Measuring how far a workpiece is out of square
  1. Try a blade in the gap
  2. The correct blade is the one that fits with a slight drag: it slides but you feel it
  3. A blade that slips freely is too thin; one that will not enter is too thick
  4. Blades can be stacked to make up an intermediate thickness
  5. Wipe clean and oil lightly, since they rust readily

Step 4: micrometers

More precise than a calliper, reading to 0.01mm or better, over a limited range.

  • An external micrometer typically covers 0 to 25mm, with larger frames for larger ranges
  • Use the ratchet or friction thimble for the final turn, which applies consistent pressure. This is what makes readings repeatable
  • Check the zero before use
  • Rarely needed for household work, and useful for engineering and restoration

Step 5: common measurements

  • Pipe: UK copper and plastic pipe is sized by outside diameter: 10, 15, 22 and 28mm. Measure the outside
  • Bolt diameter: measured across the thread crests. M8 is nominally 8mm
  • Thread pitch: the distance between adjacent crests. Use a thread pitch gauge, or measure across ten threads and divide
  • Spanner size is the distance across the flats, not the bolt diameter. An M8 bolt commonly takes a 13mm spanner
  • Drill bits: measure the shank, not the flutes, since the cutting edges may be worn
  • Sheet thickness: measure at several points and away from the edge

Step 6: temperature and touch

At this level of precision, small effects matter.

  • Metal expands with temperature; a component just off a machine reads larger
  • Holding a workpiece warms it
  • Let items reach room temperature for precise work
  • Handle by the edges where possible

Care

  • Keep the jaws and the beam clean. Grit ruins accuracy and wears the sliding surfaces
  • Store in the case, not loose in a toolbox
  • Do not drop it; a bent jaw is unrecoverable
  • Wipe with a lightly oiled cloth
  • Remove the battery from a digital calliper for long storage, since it drains and can leak
  • Check the zero regularly
  • Never use a calliper as a scriber, a screwdriver or a clamp

Cheaper alternatives

  • Drill gauge: a plate with graded holes, identifying a drill size instantly
  • Thread pitch gauge: leaves matching a thread by shape
  • Radius gauge: for internal and external radii
  • A steel rule with fine graduations and a magnifier gets closer than you would think
  • Take the part to the merchant and match it against stock, which is frequently the fastest answer

If it goes wrong

Reading not repeatable: inconsistent pressure, or dirt on the jaws.

Calliper does not read zero closed: dirt in the jaws, or it needs re-zeroing.

Measurement varies round a component: it is not perfectly round. Take several and note the range.

Part still does not fit: check whether it is a nominal size rather than an actual one.

Digital display erratic: low battery, or moisture in the tool.