Back to Repairs

Damp Proof Courses Explained

Damp Proof Courses Explained
DIY Guides Editorial 14 March 2026

A damp proof course is a horizontal barrier built into a wall near ground level to stop moisture rising through the masonry. Most damp problems at low level are about it being bridged rather than absent.

What it is

A continuous impermeable layer in a mortar course, near the base of the wall.

Materials used over the years:

  • Slate: Victorian and Edwardian, one or two courses of slate laid in mortar
  • Engineering brick: dense bricks with very low absorption, used as a DPC course
  • Bitumen felt: mid twentieth century
  • Polythene or plastic: modern, black plastic visible in the mortar joint
  • Injected chemical: retrofitted, sometimes visible as a line of small filled holes

Houses built before about 1875 frequently have no DPC at all, because they predate the requirement and were built to breathe instead.

Step 1: find yours

  1. Go outside and look at the base of the wall
  2. Look for a distinct line in the mortar course, two or three brick courses above ground
  3. A black plastic strip, a slate layer or a thicker mortar joint
  4. Look for a line of small filled holes at regular intervals, which indicates a chemical injection DPC
  5. Follow it around the whole building and note where it is obscured
  6. Photograph it

Where it is completely hidden by render or by ground level, that is itself the finding.

The 150mm rule

The DPC should be at least 150mm above the finished ground level, which is roughly two brick courses.

The reason is splashing: rain hitting a hard surface bounces up the wall, and 150mm keeps that splash below the barrier.

Where the ground has risen over the years, through added paving, decking, gravel, or garden soil, the DPC is bridged and ground moisture bypasses it entirely.

The ways a DPC gets bridged

External:

  • Raised ground level: a new patio, path, driveway or decking laid over the old level
  • Flowerbeds and soil banked against the wall
  • Render carried down over the DPC to ground level, providing a moisture path across it
  • Debris in the cavity at the base, mortar droppings forming a bridge between the leaves
  • An added step or ramp against a door threshold
  • Gravel or bark piled against the wall

Internal:

  • A solid floor screed carried over the DPC without a damp proof membrane linked to it
  • Plaster carried down to the floor, bridging from below the DPC to above it
  • An internal wall abutting an external wall without its own DPC

Step 2: fix the bridging

Frequently the cheapest and most effective damp repair available.

  1. Identify where the ground or the render crosses the DPC line
  2. Lower the ground level to at least 150mm below the DPC. Dig out soil, lift paving, remove gravel
  3. Where the level cannot be lowered, form a drainage channel along the wall: a gravel-filled trench, or a channel drain, taking water away
  4. Where render bridges the DPC, cut it back to above the DPC line and form a bell mouth or a drip so water sheds clear
  5. Clear any debris from the base of the cavity, which may need bricks removing
  6. Make sure the ground falls away from the building

Never render, paint or seal over a DPC. It defeats the whole purpose.

Step 3: check the drainage while you are there

  • Gullies clear and free draining
  • Downpipes discharging into the gully, not onto the ground
  • No overflowing gutter above the affected area
  • No leaking underground drain
  • Ground sloping away from the building

Damp proof membranes

A DPC deals with walls. A damp proof membrane does the same job for a solid floor.

  • A sheet of polythene or a liquid applied layer beneath or within a concrete floor slab
  • It should be linked to the wall DPC so there is a continuous barrier
  • Older solid floors frequently have none, and damp appears at the floor edges
  • Symptoms include damp or lifting flooring, particularly around the perimeter

When a new DPC is needed

  • Where there is genuinely no DPC and rising damp has been independently confirmed
  • Where the original has failed, which slate and bitumen can do
  • Where bridging cannot practically be removed

Methods are chemical injection cream into drilled holes, or physically cutting a new DPC into the mortar course.

Get an independent diagnosis first, from someone who does not carry out the remedial work.

Older and listed buildings

Solid-walled buildings without a DPC were designed to absorb and release moisture through breathable lime mortar and plaster.

Adding impermeable cement render or injecting a barrier can trap moisture rather than solving anything.

Take advice from someone experienced in traditional construction, and check listed building consent requirements before altering the external walls.

If it goes wrong

Damp at low level despite a DPC: it is bridged. Check the ground level and the render.

Cannot find the DPC: it may be buried, rendered over, or the building may predate them.

Damp returned after lowering the ground: another bridge remains, or the cause is different.

Damp along the floor edges: the floor membrane, not the wall DPC.

New patio caused damp: it has been laid over the DPC. It needs lowering or a drainage channel.

Cavity trays

A related component worth knowing about.

Where something interrupts a cavity, a tray directs any water in the cavity outward through weep holes rather than letting it run down onto the interruption.

  • Above windows and doors
  • Where a lean-to or extension roof abuts the wall
  • At a change in level
  • Around a chimney stack

A missing or damaged cavity tray shows as damp at a specific level, frequently just above an opening or where a roof meets the wall.

A summary

  1. Find the DPC and photograph it all the way round
  2. It must be at least 150mm above finished ground level
  3. Lower any ground, paving or planting that bridges it
  4. Cut back render carried down over it
  5. Never seal, paint or render over a DPC