Back to Repairs

Fixing Penetrating Damp

Fixing Penetrating Damp
DIY Guides Editorial 14 March 2026

Penetrating damp is water finding a way in from outside. The internal symptom is the last thing to fix; the repair is always on the outside.

How to recognise it

  • A defined damp patch rather than general mould
  • Can be at any height, including well above a metre
  • Worse during and after rain, particularly wind-driven rain from one direction
  • Frequently on one elevation only, usually the most exposed
  • Staining and tide marks on the plaster
  • Plaster may be blown, soft or crumbling
  • Improves in dry spells

Step 1: the external inspection

Go outside and look at the wall from the position corresponding to the damp inside.

Work from the top down.

  1. Roof: slipped, cracked or missing tiles or slates. Check with binoculars from the ground
  2. Flashings: at chimneys, abutments, roof junctions and around dormers. Lifted, cracked, or with failed mortar fillets
  3. Chimney: cracked pots, defective flaunching, open joints, missing or failed lead
  4. Gutters: blocked, overflowing, sagging, leaking at joints, falling the wrong way
  5. Downpipes: cracked, blocked, joints open, discharging against the wall, or not into a gully
  6. Render: cracked, hollow-sounding, blown, or with defective bell mouths at the base
  7. Pointing: eroded, cracked or missing mortar joints
  8. Sills: cracked, no fall, blocked drip groove
  9. Sealant around windows and doors
  10. Ground level and the DPC

Step 2: confirm the source

Guessing wastes money. Confirm before repairing.

Observation during rain: go out during heavy rain and watch. Overflowing gutters and leaking downpipe joints are obvious when it is actually raining and invisible when dry.

The hose test:

  1. Have someone watch the damp patch inside
  2. Start with a gentle hose on the wall well below the suspected area
  3. Run it for 15 to 20 minutes, then wait
  4. If nothing appears, move up a section and repeat
  5. Work upwards in stages, one area at a time
  6. When the damp appears inside, the last area wetted is the source

Working upwards in stages is what makes the test useful. Hosing the whole wall at once tells you nothing.

The usual culprits

Gutters and downpipes account for a large proportion of penetrating damp.

  • A blocked gutter overflows down the wall every time it rains
  • A leaking downpipe joint saturates one strip of wall
  • A downpipe discharging onto the ground rather than into a gully soaks the base of the wall
  • These are cheap to fix and frequently overlooked

Defective pointing lets water into the joints, particularly on an exposed elevation.

Cracked render is worse than no render: water gets in through the crack and cannot get out through the render.

Failed flashing at a chimney or abutment, which shows as damp on the chimney breast or at ceiling level.

Step 3: make the repair

Gutters and downpipes: clear, realign to fall, replace cracked sections, seal leaking joints, and make sure downpipes discharge into a gully.

Pointing: rake out the defective joints to about 20mm, brush out, and repoint with a mortar no stronger than the existing. Use lime mortar on a soft-brick or period building, since hard cement pointing forces moisture through the bricks and spalls them.

Render: hack off hollow and cracked areas back to sound render, and patch or renew. Match the material: cement render on a solid period wall can trap moisture and cause more harm than it prevents.

Flashings: generally a roofer's job. Mortar fillets are a common cheap substitute for proper lead and they crack.

Sills: repair the sill, clear the drip groove, restore the fall away from the window.

Step 4: consider water repellent treatment

Breathable water repellent coatings reduce absorption on exposed masonry.

  • Only useful where the wall is sound and the problem is general absorption on an exposed elevation
  • Not a substitute for repairing a defect. It will not fix a crack, a blocked gutter or failed pointing
  • It must be breathable, or moisture is trapped behind it and the problem worsens
  • Never use a non-breathable sealer on masonry

Step 5: let it dry, then redecorate

  1. Fix the defect and confirm the damp stops responding to rain
  2. Let the wall dry fully, which takes weeks or months
  3. Use a moisture meter rather than guessing
  4. Hack off any blown plaster and make good
  5. Seal staining with a stain-blocking primer
  6. Redecorate the whole wall

If it goes wrong

Damp continues after repair: more than one defect, or the wrong one was fixed. Hose test again.

Damp appears somewhere new after repointing: water is finding the next weakest point.

Bricks spalling after repointing: the mortar is too strong. It should be softer than the brick.

Render cracking again: movement, or the wrong material for the wall.

Cannot find the source: get a surveyor with a thermal camera, which shows moisture patterns in the structure.

Working at height safely

Much of this inspection is above ground level.

  • Use binoculars from the ground for the first look, which shows a great deal
  • Set a ladder at roughly one out for every four up, footed or tied
  • Never stand above the third rung from the top, and never overreach
  • Use a tower or scaffold for anything above single-storey height or lasting more than a few minutes
  • Never work on a roof, or from a ladder resting on a roof
  • Gutter and roof work is frequently better given to someone with proper access equipment

A summary

  1. Inspect the outside from the top down
  2. Check gutters and downpipes first, since they cause a large share of cases
  3. Confirm the source with observation during rain or a staged hose test
  4. Repair with materials no harder than the existing masonry
  5. Let the wall dry fully before redecorating