A damp meter is a useful diagnostic tool and it is widely misused, including in commercial damp reports. Knowing what it actually measures makes the readings far more useful.
What a conductance meter measures
The common two-pin damp meter passes a small current between the pins and measures the electrical resistance between them.
Wet material conducts better than dry material, so lower resistance is displayed as a higher damp reading.
It does not measure water. It measures conductivity. Anything else conductive gives the same reading.
What gives false readings
- Salts. Hygroscopic nitrates and chlorides in plaster are highly conductive. A dry but salt-contaminated wall reads as soaking wet
- Foil-backed plasterboard. Reads off the scale everywhere
- Metal: nails, screws, mesh, pipes, beads behind the plaster
- Some paints and coatings containing conductive pigments
- Carbon, including soot residues on a chimney breast
- Some timber species and treatments
This is why a damp survey based on meter readings alone is not a diagnosis. A high reading is a prompt to investigate, not a conclusion.
Types of meter
Two-pin conductance meter. Cheap and common. Measures between the pins at their depth, so it reads the surface only unless deep probes are used. Calibrated for timber, so wall readings are relative rather than absolute.
Pinless or capacitance meter. A flat pad reads a small depth into the material without marking it. Useful for scanning an area quickly, and it is affected by density and by anything metallic behind.
Hygrometer. Measures relative humidity in the air rather than in a material. The most useful instrument for diagnosing condensation.
Thermo-hygrometer with dew point. Shows air temperature, humidity and the dew point, so you can compare the dew point against a surface temperature.
Infrared thermometer. Measures surface temperature, which identifies cold spots where condensation will form.
Step 1: use it comparatively
The correct way to use a conductance meter.
- Take a reading in an area you know is dry, such as an internal wall away from the problem. This is your baseline
- Take a grid of readings across the affected area, recording each one
- Work up the wall in 200mm steps from the skirting
- Note where the readings rise and where they fall back to the baseline
- Sketch the pattern
The pattern of readings tells you far more than any single number.
Step 2: read the pattern
- High at the base, falling steadily with height, stopping below a metre: consistent with rising damp or a bridged DPC
- A defined patch at mid or high level: penetrating damp or a leak
- High only at the surface, with the wall dry behind: condensation or salts
- High everywhere including known dry areas: something is interfering, such as foil backing
- High readings with white deposits: likely salts rather than water
Step 3: diagnose condensation with a hygrometer
For condensation, a hygrometer is more useful than a damp meter.
- Place a hygrometer in the affected room and leave it
- Record the relative humidity at different times: morning, after cooking, after showering, overnight
- Aim for 40 to 60 per cent; above 65 per cent sustained encourages mould
- Measure the surface temperature of the cold wall with an infrared thermometer
- Compare that surface temperature with the dew point shown by the meter
- Where the surface is below the dew point, condensation will form there
This turns a subjective argument into two numbers that explain exactly why the mould is where it is.
Step 4: confirm properly where it matters
The definitive test for moisture in masonry is a calcium carbide or gravimetric test on a drilled sample taken from within the wall, which measures actual water content and is unaffected by salts.
These are laboratory or specialist methods and are what a rigorous damp investigation uses.
Where a substantial sum is at stake, ask whether the surveyor has done more than run a conductance meter over the surface.
Practical use at home
- Cheap meters are perfectly adequate for comparative use
- Use them to check whether a wall is drying out after a leak, by taking the same readings weekly
- Use them to compare an affected wall with a known dry one
- Do not treat a number as a verdict
- Record everything with dates
Monitoring a wall drying out
- Mark fixed measuring points on the wall in pencil
- Take a reading at each point and record it with the date
- Repeat weekly, at the same points
- A falling trend means it is drying
- A flat trend at a high level means moisture is still entering, or salts are present
If it goes wrong
Readings high everywhere: foil-backed board or metal behind the plaster. The meter is not usable there.
Readings high but the wall feels dry: salts. Confirm with a proper test before acting.
Readings not falling despite drying: salts, or moisture is still entering.
A survey quoted only meter readings: ask what else was done. Meter readings alone are not a diagnosis.
Readings differ between meters: normal. Use one meter consistently and compare its readings with each other.
What to buy
- A hygrometer: the single most useful instrument for a household, and it costs very little
- An infrared thermometer: identifies cold surfaces where condensation forms
- A basic two-pin damp meter: useful comparatively, particularly for monitoring drying
Those three together cost less than an hour of a surveyor's time and answer most household questions.
A summary
- A conductance meter measures conductivity, not water
- Salts, foil backing and metal all give false high readings
- Use it comparatively, against a known dry area
- Read the pattern of readings, not a single number
- Use a hygrometer and a surface thermometer for condensation