Every pipe, cable and duct passing through the building fabric leaves a hole around it. Individually they are trivial; collectively they frequently exceed the area of an open window.
Step 1: find them
Use an incense stick on a windy day and work through this list.
Through external walls:
- Boiler flue and condensate pipe
- Extractor fan ducts
- Waste and overflow pipes
- Outside tap supply
- Incoming water main, gas and electricity
- Aerial, satellite and broadband cables
- Outdoor socket and light cables
- Cooker hood ducting
Through floors:
- Radiator pipes coming up through the boards
- Waste pipes under sinks and basins
- Cables to sockets and lights below
- Soil pipe passing through
Through ceilings and into the loft:
- The loft hatch
- Recessed downlights
- Ceiling roses and pendant fittings
- Extractor fan housings
- Pipes and cables to the loft
- The tops of stud partitions
Within the room:
- Socket and switch boxes on external walls, which frequently connect to the cavity
- Behind kitchen units on external walls
- Inside built-in cupboards
- Around a boiler or a consumer unit
Step 2: the materials
Decorator's caulk. Small internal gaps, paintable, cheap. Not for anything moving much or anything external.
Flexible sealant. A silicone or hybrid sealant for internal joints that move, or around pipes that expand.
Low-modulus exterior sealant. Anything outside, where it must stay flexible and weather resistant.
Expanding foam. Larger voids. Use the low-expansion type; standard foam expands with surprising force and can distort a frame or crack plaster. Trim flush when cured and seal or cover it, since foam degrades in sunlight.
Mineral wool. Packing a large gap before sealing over it, and the correct material where fire performance matters.
Pipe collars and rosettes. Purpose-made plastic or metal covers giving a neat finish around a pipe through a floor or a wall.
Backing rod. Foam rope pushed into a deep gap before sealing, so the sealant forms a proper joint rather than filling a void.
Step 3: seal pipes through floors
- Vacuum around the pipe thoroughly
- Small gap: apply flexible sealant around the pipe
- Larger hole: pack with mineral wool, then seal over, or use low-expansion foam trimmed flush
- Fit a pipe collar or rosette over the top for a neat finish
- Leave enough tolerance for the pipe to move, or it will tick and creak as the heating warms up
- Do not seal a pipe so rigidly that it cannot expand
Step 4: seal penetrations through external walls
- Rake out any failed or perished sealant
- Clean and dry the opening
- Pack a large void with mineral wool or backing rod
- Apply a low-modulus exterior sealant outside, tooled to a neat profile
- Seal the internal side as well, which is where the draught is felt
- Check the penetration slopes slightly outward, or seal so water cannot track in
Step 5: sockets and switches
A frequent and surprising source on external walls, since the box can open directly into a cavity or a void.
Safety first.
- Isolate the circuit at the consumer unit and lock it off
- Prove dead with an approved voltage indicator before removing any faceplate
- Ease the faceplate forward
- Seal around the outside of the box, where it meets the plaster, with caulk or sealant
- Fit a proprietary socket box draught seal, a moulded gasket that sits behind the faceplate
- Do not fill the inside of the box with foam or sealant. The accessory needs space, the cables need to be reachable, and materials must not obstruct the fitting
- Refit the faceplate and restore power
Where you are not confident working at a socket, an electrician can fit seals quickly, or seal the plaster line externally only.
Step 6: the loft side
- Seal around pipes and cables where they pass through the ceiling into the loft
- Use fire-rated covers over recessed downlights, not loose insulation
- Check the tops of stud partitions, which can be entirely open into the loft
- Insulate any ducting passing through the loft, or moist air condenses inside it
- Check every extractor duct actually reaches outside
What not to seal
- Anything that is a vent. Air bricks, combustion air vents, trickle vents, passive stack terminals
- The boiler flue and its clearances, which have specified requirements
- Anything around a gas pipe where the seal is required to be by a particular method. Gas work is for a Gas Safe registered engineer
- The inside of an electrical box
- Weep holes in the outer leaf of a cavity wall, or in a window frame, which let water out
- Drainage slots in a window or door frame
Weep holes look like unnecessary gaps and are drainage. Sealing them causes water to back up inside the wall or the frame.
Step 7: fire safety
- Where a penetration passes through a fire-resisting element, such as a ceiling under a loft conversion or a wall to an integral garage, it must be sealed with an appropriate fire-stopping product
- Ordinary foam and sealant are not fire-stopping materials
- Intumescent products and fire-rated collars are made for the purpose
- Take advice where you are unsure whether an element is fire-resisting
If it goes wrong
Pipes ticking after sealing: sealed too rigidly. Ease it so the pipe can move.
Foam expanded and cracked the plaster: standard foam was used. Low-expansion foam only.
Foam crumbling outside: it degrades in sunlight. Trim and cover with sealant.
Damp appeared at a sealed penetration: water may be tracking in. Check the fall and the external seal.
Draught still coming from a socket: seal around the box at the plaster line as well as behind the faceplate.