Replacing a ceiling light looks simple and catches people out, because a typical ceiling rose contains more conductors than the fitting needs.
Why there are so many wires
Most UK lighting is wired loop-in. The permanent live is looped from rose to rose along the circuit, so a ceiling rose typically contains:
- A cable in from the previous light
- A cable out to the next light
- A cable down to the switch
- The flex to the lampholder
That is three cables plus the flex, and up to nine conductors in one small enclosure.
The terminals in a loop-in rose
Working out which is which is the whole job.
- The loop terminal, sometimes marked LOOP or with three permanent lives together. These are permanently live and are not connected to the lamp. They simply pass through
- The neutral terminal. Blues from the in and out cables, plus the flex neutral
- The switched live terminal. The conductor returning from the switch, plus the flex live
- The earth terminal. All earths together
The permanent lives in the loop terminal stay live even with the switch off. That is why isolating at the consumer unit, not the wall switch, matters here more than anywhere.
Before starting
- Not in a bathroom. Notifiable everywhere in the UK
- Where there is no earth conductor, fit a double insulated fitting only, never a metal one
- If the wiring is rubber or fabric insulated, stop and call an electrician
What you need
- The new fitting, with its instructions and fixings
- Insulated screwdrivers
- An approved voltage indicator and a proving unit
- An MCB lock-off device
- Brown and green and yellow sleeving
- Connector blocks or approved connectors, if needed
- A camera, labels and a torch
- A stepladder, and someone to help
Step 1: isolate and prove dead
- Turn off the lighting circuit at the consumer unit and lock it off
- Turn the wall switch on as well, so the switched live is not left isolated at the switch only
- Confirm the light does not work
- Remove the rose cover
- Prove dead across every conductor and every combination, using prove, test, prove
Step 2: photograph and label
This is the step that makes the job possible.
- Photograph the terminal block from several angles, in good light
- Photograph again close up, so the individual conductors are clear
- Label each conductor with tape and a pen before removing anything: loop, neutral, switched live, earth
- Count the cables and note how many conductors are in each terminal
- Note which conductors are sleeved
If the new fitting has fewer terminals than the rose, the loop conductors will need connecting together in an approved connector, which must remain accessible for inspection.
Step 3: check the new fitting
- Read the instructions before disconnecting anything
- Check whether it needs an earth. A double insulated fitting, marked with two concentric squares, does not
- Check the weight. A ceiling rose is not a structural fixing
- Check the maximum lamp wattage stated on the fitting
- Check whether it is suitable for the ceiling type
- Check whether the fitting covers the existing hole and any old paint mark
Step 4: supporting the weight
A significant point with modern fittings.
- A standard ceiling rose and a plasterboard ceiling will not carry a heavy fitting
- Anything more than about 2kg needs a proper fixing into a joist, or a timber noggin fitted between joists
- A chandelier or a large pendant needs a substantial fixing and possibly a ceiling plate
- Plasterboard fixings alone are not adequate for a heavy fitting overhead
- A light fitting falling from a ceiling is a serious matter. Where you are unsure, get it fitted properly
Step 5: connect the new fitting
- Connect the permanent lives together in their own connector, insulated and kept accessible
- Connect the neutrals together with the fitting's neutral
- Connect the switched live to the fitting's live
- Connect all earths together and to the fitting's earth terminal, sleeved green and yellow
- Make sure no bare copper is exposed outside any terminal
- Tug each conductor to confirm it is held
- Ensure nothing is trapped as the fitting goes up
Step 6: fit and test
- Fix the fitting securely to the ceiling using an adequate fixing
- Fit the lamp, within the stated maximum wattage
- Remove the lock-off and restore power
- Test with the switch, and both switches if two-way
- Check the fitting is secure and not warm after a period of use
If it goes wrong
Light stays on permanently: the permanent live has been connected to the lamp instead of the switched live. Isolate and correct immediately.
Light does not work: the switched live has not been connected, or a conductor is loose.
Circuit trips: a misconnection. Isolate and recheck against your photograph.
Other lights on the circuit stopped working: the loop conductors have not been reconnected together.
Cannot work out the wiring: restore it as photographed and call an electrician.
A summary
- A loop-in rose contains permanent lives that stay live with the switch off
- Isolate at the board, with the wall switch left on, and prove dead
- Photograph and label every conductor before disconnecting
- Keep the loop conductors joined together in an accessible connector
- Support the weight properly; a rose is not a structural fixing
- No earth means a double insulated fitting only
Downlights
Replacing a pendant with recessed downlights is a bigger job than it looks.
- It involves cutting the ceiling and running new cable, which may constitute a new circuit
- Fire-rated downlights are required where the ceiling forms part of a fire separation, such as between storeys or under a loft conversion
- Insulation must not simply be laid over a fitting unless it is rated for it
- Check joist positions before cutting
- Realistically an electrician's job