Replacing a damaged or dated socket faceplate with a like-for-like one on an existing circuit is generally non-notifiable work in England, outside special locations. It still has to be done properly.

Before starting

  • In a bathroom or shower room this is notifiable work everywhere in the UK. Use a registered electrician
  • In Wales, kitchen and outdoor work remains notifiable
  • If the existing socket is scorched, cracked or warm, there is a fault. Get it investigated rather than simply fitting a new plate
  • If the wiring behind looks old, brittle or has no earth, stop and call an electrician

What you need

  • A matching replacement socket
  • A screwdriver set, insulated
  • An approved voltage indicator and a proving unit
  • An MCB lock-off device
  • Green and yellow earth sleeving
  • A torch and a camera
  • Wire strippers and side cutters

Step 1: isolate and prove dead

  1. Identify the correct circuit at the consumer unit
  2. Switch the breaker off and lock it off
  3. Tell everyone in the house
  4. Confirm the socket is dead by plugging something in
  5. Remove the faceplate screws and ease the plate forward without pulling the cables
  6. Prove dead: prove the tester on a known live source, test line to neutral, line to earth and neutral to earth at the socket terminals, then prove the tester again

Do not skip the proving. A socket in a room can be on a different circuit from the one you assumed.

Step 2: photograph and record

  1. Photograph the connections clearly before touching anything
  2. Note how many cables are present
  3. Two cables: a ring final circuit. Two browns in L, two blues in N, two earths in E
  4. One cable: the end of a radial, or a spur
  5. Three cables: a spur has been taken from this socket. Note this carefully
  6. Label the conductors with tape if there is any chance of confusion

Step 3: disconnect

  1. Loosen each terminal and withdraw the conductors
  2. Keep the pairs together as you remove them
  3. Inspect the conductor ends: any that are nicked, discoloured or blackened should be cut back and re-stripped
  4. Check inside the box for damage or overheating

Step 4: check the box

  • Check the box is secure in the wall and not cracked
  • Check the fixing lugs are sound and the screws bite
  • Check the depth. A shallow box, 25mm, may not accommodate a modern plate with more depth behind it. Forcing conductors into too little space damages insulation
  • Where the box is too shallow, it needs replacing, which means cutting the wall
  • Check for sharp edges and that any grommet is in place where cables enter a metal box

Step 5: the earth arrangements

The part most often got wrong.

  • Every bare earth conductor must be sleeved in green and yellow for its full exposed length inside the box
  • A plastic faceplate on a plastic box: earths connect to the plate's earth terminal
  • A metal faceplate on a metal box: the earths connect to the plate, and there must additionally be an earth flylead from the metal box's earth terminal to the faceplate. The fixing screws are not an acceptable earth path
  • A metal faceplate on a plastic box: the earths go to the plate

Missing the flylead on a metal box is a very common amateur fault.

Step 6: connect the new plate

  1. Connect brown conductors to L, blue to N, and sleeved earths to E
  2. On a ring, both browns go into the same L terminal, both blues into N, both earths into E
  3. Insert conductors fully so no bare copper is visible outside the terminal
  4. Tighten each terminal firmly and tug each conductor gently to confirm it is held
  5. Check the screw is clamping copper, not insulation
  6. Fit the earth flylead if the box is metal

Step 7: fit and test

  1. Fold the conductors carefully back into the box in a concertina, without straining or trapping them
  2. Offer the plate up and check nothing is pinched
  3. Fit and tighten the fixing screws evenly, so the plate sits flat and square
  4. Remove the lock-off and restore power
  5. Test with a plug-in socket tester, which confirms basic polarity and earth continuity
  6. Check the plate is not warm after a period of use

A plug-in socket tester is inexpensive and worth owning. It is a basic check, not a substitute for proper testing.

What not to do

  • Do not add a new spur without knowing the circuit can take it
  • Do not convert a single socket to a double by simply fitting a bigger plate to a shallow box
  • Do not extend conductors with connector blocks buried in a wall
  • Do not fit a socket in a bathroom
  • Do not proceed if anything does not match what you expected

If it goes wrong

Socket tester shows a fault: isolate and recheck the connections against your photograph.

RCD trips on restoring power: a conductor is misconnected or trapped. Isolate and check.

Plate will not sit flat: the box is too shallow or the conductors are badly folded.

Found three cables and are unsure: photograph it, restore it as it was, and get advice.

Anything scorched inside: there is a fault. Call an electrician.

A summary

  1. Isolate at the board, lock off, and prove dead before touching anything
  2. Photograph the connections before disconnecting
  3. Sleeve every bare earth in green and yellow
  4. A metal plate on a metal box needs an earth flylead as well
  5. Check the box depth before buying a deeper faceplate
  6. Test with a plug-in socket tester afterwards