Back to Repairs

Fixing a Running Toilet

Fixing a Running Toilet
DIY Guides Editorial 20 March 2026

A continuously running toilet can waste hundreds of litres a day. There are only two possible causes and a simple test tells you which.

How a cistern works

Two valves.

The fill valve, or float valve, lets water in and shuts off when the float reaches the set level.

The flush valve sits in the bottom of the cistern and releases the water into the pan when you flush, then reseals.

Water running continuously means one of them is not sealing.

Step 1: the dye test

Identifies the fault in ten minutes with no dismantling.

  1. Take the cistern lid off
  2. Add a few drops of food colouring, or a little instant coffee, to the cistern water
  3. Do not flush
  4. Wait 15 to 20 minutes
  5. Look in the pan

Coloured water in the pan means the flush valve is leaking.

No colour in the pan, but water still running, means the fill valve is overfilling and water is going out through the overflow.

Step 2: check the water level

Look inside the cistern.

  • There is usually a marked water line
  • The level should sit about 25mm below the overflow
  • Water at or above the overflow means the fill valve is set too high or not shutting off

On a modern toilet the overflow discharges internally into the pan, which is why the pan trickles rather than water appearing outside.

What you need

  • Replacement flush valve seal, diaphragm, or a complete valve
  • Replacement fill valve if needed
  • An adjustable spanner and grips
  • A screwdriver
  • A sponge and a bucket
  • Towels
  • A camera or phone for photographs

Fault A: the fill valve

Water level too high, or it never shuts off.

First, try adjusting it:

  • Modern float on a vertical stem: a screw or a clip adjusts the height. Lower it so the water stops 25mm below the overflow
  • Older brass arm and ball float: bend the arm gently downward, or turn the adjusting screw where fitted
  • Flush and check the level, and adjust again

If adjusting does not work, the valve is worn:

  1. Close the isolating valve on the supply pipe, turning the slot across the pipe
  2. Flush to empty the cistern and sponge out the remainder
  3. Disconnect the supply pipe from the valve
  4. Undo the back nut holding the valve to the cistern
  5. Lift the old valve out
  6. On an older diaphragm valve, the diaphragm washer alone can often be replaced, which is cheap
  7. Otherwise fit a complete new fill valve, which is inexpensive and usually easier
  8. Fit the new valve with its washers in the correct order
  9. Reconnect, restore the water slowly and set the level

Fault B: the flush valve

Coloured water reaching the pan means the seal at the bottom of the cistern is not sealing.

  1. Close the isolating valve and flush to empty the cistern
  2. Sponge out the remaining water
  3. Photograph the assembly before dismantling
  4. On most modern cisterns the flush valve lifts and twists out from inside, once the flush mechanism is disconnected
  5. Inspect the large rubber seal or the diaphragm
  6. A perished, split or distorted seal is the fault
  7. Clean any limescale and grit from the seat it sits on, which is a common cause
  8. Fit a new seal, or a complete new flush valve
  9. Reassemble, restore the water and test

On a close-coupled toilet, replacing the whole flush valve means lifting the cistern off the pan, which is heavier and more awkward.

Older siphon flush

Cisterns with a lever and a plastic siphon rather than a push button.

  • A siphon cannot leak into the pan continuously; it either works or it does not
  • A siphon that needs several pulls to flush has a split diaphragm
  • The diaphragm is a cheap plastic washer, replaceable by lifting the siphon out
  • A siphon type that will not flush is a different fault from a running toilet

Limescale

In hard water areas, scale on the valve seat is a frequent cause of a poor seal.

  • Clean the seat thoroughly when the valve is out
  • A descaler or vinegar soak on removable parts helps
  • Do not scratch the sealing face, which makes it worse

Step 3: check it is fixed

  1. Restore the water and let the cistern fill
  2. Check the level sits 25mm below the overflow
  3. Listen: it should fill and then stop completely
  4. Repeat the dye test after a few hours
  5. Check for leaks around the cistern and the connections

If it goes wrong

Still running after a new seal: the seat is scaled or damaged. Clean it, or fit a complete valve.

Cistern fills very slowly: the isolating valve is partly closed, or the fill valve is scaled.

Water hammer when it fills: a worn fill valve, or high pressure. A modern valve or a pressure reducing valve helps.

Leaking between cistern and pan: the doughnut washer on a close-coupled toilet needs replacing.

Overflow pipe dripping outside: an older external overflow, meaning the fill valve is not shutting off.

How much it wastes

A continuously running toilet can waste in the region of 200 to 400 litres a day, and considerably more where the leak is substantial.

On a water meter that is a noticeable cost, and it is one of the commonest causes of an unexplained rise in a water bill.

The parts to fix it usually cost a few pounds.

A summary

  1. Do the dye test to identify which valve is at fault
  2. Colour in the pan means the flush valve; no colour means the fill valve
  3. Try adjusting the fill valve level before replacing anything
  4. Clean limescale from the valve seat, which is a common cause
  5. Photograph the assembly before dismantling it