A toilet that needs two pulls, or that flushes weakly, has a small number of possible causes. Work through them in order of likelihood.

Step 1: check the water level

The commonest and easiest cause.

  1. Take the cistern lid off
  2. Look for the marked water line inside
  3. The level should sit about 25mm below the overflow
  4. A low level means less water and less force in the flush
  5. Adjust the fill valve upward: a screw or clip on a modern float, or gently bend the arm upward on an older ball float
  6. Flush and test

Note that a brick or a water-saving bag in the cistern reduces the flush volume, which may be why it is weak.

Step 2: identify the mechanism

Siphon: operated by a lever handle. A plastic dome and tube inside the cistern. Common in older installations and in the UK generally until the 2000s.

Flush valve, or drop valve: operated by a push button, usually dual flush. Sits in the bottom of the cistern and lifts to release the water.

Fault A: split siphon diaphragm

The classic cause of a toilet needing several pulls.

The diaphragm is a thin plastic membrane inside the siphon that lifts the water over the bend. When it splits, water passes through it instead of being lifted, so the siphon cannot get started.

The symptom is characteristic: the first pull does nothing much, the second or third works.

The part costs very little.

  1. Close the isolating valve on the supply
  2. Flush to empty the cistern and sponge out the rest
  3. Disconnect the flush handle linkage from the siphon
  4. Underneath the cistern, undo the large back nut holding the siphon to the cistern base. On a close-coupled toilet this means lifting the cistern off the pan first
  5. Lift the siphon out
  6. Separate the siphon body and lift out the split diaphragm
  7. Fit a new one of the same size, the right way up
  8. Reassemble with new washers on the siphon base
  9. Refit, reconnect, restore the water and test

On a close-coupled toilet this is a moderately involved job, since the cistern has to come off. On a separate high or low level cistern it is much easier.

Fault B: dual flush button not operating fully

  1. Remove the flush button: usually a threaded ring unscrews from around it
  2. Check the two push rods underneath. They should be adjusted so each just contacts the valve
  3. Adjust the rod length where the design allows
  4. Check the button assembly is not scaled or sticking
  5. Check the valve lifts freely by operating it by hand inside the cistern

A dual flush that only ever gives the short flush usually has a rod adjustment problem.

Fault C: flush valve not opening fully

  • Check the valve lifts fully and drops back cleanly when operated by hand
  • Check nothing is fouling it inside the cistern
  • Check the float on the valve, which controls how long it stays open, is set correctly
  • Scale on the valve stem makes it sluggish; clean it

Fault D: blocked rim holes

A common cause in hard water areas, and easily missed.

Water enters the pan through small holes around the underside of the rim. Limescale blocks them, so the flush dribbles down one side instead of swirling round.

  1. Feel under the rim with a gloved finger and locate the holes
  2. Use a small mirror and a torch to see them
  3. Clear each hole with a piece of stiff wire, a bent coat hanger or a small screwdriver
  4. Apply a limescale remover suitable for ceramics and leave it as directed
  5. Flush several times
  6. Repeat if the swirl is still uneven

Wear gloves and eye protection with descaler, and never mix it with bleach or any other product.

Fault E: a partial blockage

A pan that empties slowly, or that flushes weakly and then gurgles, may have a partial blockage in the trap or beyond.

  • Try a flange plunger
  • Try a closet auger
  • Check whether other fittings are slow, which points to the drain

Fault F: a blocked or restricted soil vent

The soil pipe needs to vent to atmosphere, usually above the roof, so air can enter as water leaves.

  • A blocked vent, frequently by a bird's nest, causes slow flushing and gurgling from other fittings
  • Check the vent terminal at roof level from the ground with binoculars
  • An air admittance valve inside may have failed
  • Gurgling from a nearby sink or bath when the toilet flushes is the classic symptom

If it goes wrong

Needs two pulls: split siphon diaphragm. Replace it.

Flush weak and one-sided: blocked rim holes. Clear and descale them.

Only ever the short flush: dual flush rod adjustment.

Flushes but drains slowly: a partial blockage in the pan or the waste.

Gurgling from the sink when flushed: a soil vent problem. Worth getting checked.

A summary

  1. Check the water level sits 25mm below the overflow
  2. Identify whether it is a siphon or a flush valve
  3. A toilet needing two pulls almost always has a split siphon diaphragm
  4. Check the dual flush rods are adjusted correctly
  5. Clear and descale the rim holes, which is frequently overlooked

How long it takes

Checking the level and the rim holes takes twenty minutes.

Replacing a siphon diaphragm on a separate cistern is an hour; on a close-coupled toilet it is half a day, because the cistern has to come off the pan and the doughnut washer should be renewed while it is off.

Have the parts and new washers before starting, since the toilet will be out of use.