Gutter leaks are nearly always at a joint, a bracket or an outlet rather than in the middle of a length. Finding exactly where takes a hose and ten minutes.
Step 1: find the leak
- Go out during heavy rain and watch. This is the single most useful diagnostic step
- Or run a hose into the gutter and walk along below, watching
- Note whether water drips from a joint, runs over the front edge, or comes from behind the gutter
- Look for staining on the wall below, which marks a long-standing leak position
- Look for green algae or moss growth on the wall, which shows where water runs
- Photograph the position for reference
Step 2: read the symptom
- Dripping from a joint: the seal has perished or the joint has moved
- Overflowing along the front edge: blocked, or the fall is wrong, or the gutter is undersized for the roof area
- Water running behind the gutter: the gutter is set too low, or there is no drip edge on the felt, so water runs behind rather than into it
- Dripping from a bracket: the gutter is distorted, or the bracket has failed
- Splitting along a length: UV degradation, frost damage or impact
- Leaking only in heavy rain: capacity or fall, not a seal
What you need
- Replacement union seals or clips, matching the profile
- Gutter sealant, or a butyl or silicone product suitable for the material
- Replacement brackets
- A screwdriver and a drill
- Stainless or coated screws
- Wire wool and a cloth, and a degreaser
- A ladder with a standoff, or a tower
- Gloves and eye protection
Fix 1: remake a union joint
The most common repair on a plastic gutter.
- Support the gutter each side of the union
- Release the union: most have a clip that levers open, or the gutter springs out of the retaining lip
- Ease the gutter ends out of the union
- Remove the old rubber seal from inside the union
- Clean the union and the gutter ends thoroughly with a degreaser, removing all dirt, algae and old sealant
- Fit a new seal of the correct profile, seated fully in its groove
- Refit the gutter ends into the union, seating them fully
- Close the clip
- Flush with a hose and check
Leave an expansion gap. Plastic gutter expands and contracts noticeably with temperature. Most unions have moulded marks showing how far the gutter should enter; leave the gap indicated. Butting the ends hard together causes the gutter to buckle in summer and the joint to open in winter.
Fix 2: seal a joint
A quicker repair where a new seal is not available or the joint is otherwise sound.
- Clean and dry the joint thoroughly, inside and out
- Apply a gutter sealant to the inside of the joint, where the water is
- Smooth it into the joint
- Let it cure fully before testing
Sealant is a repair rather than a proper remake. It has a limited life and will need doing again.
Fix 3: a sagging run
- Sight along the gutter, or run a string line, to find the low point
- Check whether a bracket has broken, come loose, or is missing
- Replace any broken bracket
- Add extra brackets, aiming for around 800mm to 1m centres and closer at joints and outlets
- Fix brackets into sound timber. Where the fascia is soft, the fascia needs repairing first
- Recheck the fall by flushing with a hose
Fix 4: correct the fall
- Establish the level at the outlet end
- Run a string line from there to the far end, set to fall roughly 3mm per metre towards the outlet
- Release the gutter from its brackets
- Reposition the brackets to the string line, working along
- Refit the gutter and flush to check no standing water remains
Fix 5: water running behind the gutter
Common on older roofs and a frequent cause of rotten fascias.
- The roofing felt should overhang into the gutter. Where it has perished or was cut short, water runs behind
- Fit an eaves protector or a felt support tray, which carries the water forward into the gutter. This means lifting the bottom course of tiles, so it is usually a roofer's job
- Alternatively the gutter may be set too low or too far out
- Left alone, this rots the fascia and the rafter ends
Fix 6: cast iron gutters
Common on older and period properties, and a different proposition.
- Joints are bolted and bedded in mastic or putty
- Leaks are usually failed bedding, or a rusted bolt
- Sections are extremely heavy; a length of cast iron gutter is a two-person lift
- Repair involves cleaning the joint, rebedding and refitting a new bolt
- Rust must be treated and the inside painted with a suitable bituminous or metal paint
- Do not replace cast iron with plastic on a listed building or in a conservation area without checking consent
- Realistically a specialist job
When the gutter needs replacing
- Plastic that has gone brittle, chalky and cracked with UV degradation
- Multiple splits along a run
- Repeated joint failures
- Undersized for the roof area, overflowing in heavy rain
- Cast iron with extensive corrosion
If it goes wrong
Joint leaks again after a new seal: the gutter ends may be distorted or dirty. Clean and check they seat fully.
Sealant repair failed: it was applied to a wet or dirty surface, or to the outside.
Gutter buckling in summer: no expansion gap was left at the joints.
Still overflows in heavy rain: the gutter or the downpipe may be undersized.
Fascia soft where brackets fix: the fascia needs repairing before the gutter can be secured.
A summary
- Watch during rain, or run a hose, to find exactly where it leaks
- Most leaks are at a union where the seal has perished
- Clean thoroughly and fit a new seal rather than relying on sealant
- Always leave the moulded expansion gap in a union
- Add brackets at 800mm to 1m centres to cure a sag
- Water running behind the gutter needs an eaves protector tray