Back to Repairs

Replacing Guttering and Downpipes

Replacing Guttering and Downpipes
DIY Guides Editorial 10 April 2026

Replacing plastic guttering is well within reach for a single-storey run. The work is in setting it out accurately, not in the fitting.

Safety

All the working at height rules apply: standoff bracket, 4 to 1, tied or footed, no overreaching, and a tower for anything sustained.

Above single-storey height, get a contractor with proper access.

Step 1: identify the profile

Gutter profiles are not interchangeable between manufacturers, and sometimes not within a range.

Common UK profiles:

  • Half round: the traditional semicircular section, in 112mm and 150mm
  • Square: a squared section, 114mm
  • Ogee or Deepflow: a decorative or high-capacity profile, popular on newer housing
  • Round downpipes: 68mm typically
  • Square downpipes: 65mm typically

Take an offcut to the merchant, or photograph the profile end-on with a tape measure alongside. Mixing brands rarely works.

Step 2: work out the sizes

  • Larger roof areas need larger gutters and downpipes
  • A gutter that overflows in heavy rain may be undersized rather than blocked
  • Deepflow or high-capacity profiles handle more water in the same visual width
  • One downpipe typically serves a limited length of gutter; a long run may need two
  • Ask the merchant to check the capacity against your roof area

What you need

  • Gutter lengths, unions, stop ends, angles, outlets and brackets
  • Downpipe, brackets, offsets or a swan neck, and a shoe
  • Stainless or coated screws
  • A drill driver, and a masonry drill for downpipe brackets
  • A fine tooth saw, and a file
  • A string line, a level and a tape measure
  • A ladder with a standoff, or a tower
  • Gloves and eye protection

Step 3: remove the old

  1. Start at one end and work along
  2. Release the unions and lift each length out
  3. Lower everything to the ground rather than dropping it
  4. Remove the old brackets
  5. Inspect the fascia thoroughly once it is exposed. Rot behind a gutter is very common and must be repaired before the new gutter goes on
  6. Repair or replace any damaged fascia now, since it is far harder later

Step 4: set the fall

The step that determines whether it works.

  1. Decide the outlet position, usually at an existing downpipe
  2. Fix the bracket at the highest point first, at the far end of the run
  3. Set the height so the gutter sits below the roof line, with the tile overhanging into it. A common guide is that a straight edge laid down the roof slope should just clear the front edge of the gutter
  4. Fix a bracket at the outlet end, lower by the required fall
  5. Fall of roughly 3mm per metre, or as the manufacturer states
  6. Run a taut string line between the two brackets
  7. Fix all the intermediate brackets to the string line

Too little fall and water stands; too much and it looks wrong and can overshoot the outlet in heavy rain.

Step 5: bracket spacing

  • Around 800mm to 1m centres, or as the manufacturer specifies
  • A bracket within 150mm each side of every joint, angle and outlet
  • Closer spacing in areas subject to snow load
  • Fix into sound timber, with the screw fully home
  • Where there is no fascia, rafter brackets or rise-and-fall brackets are used

Step 6: fit the gutter

  1. Cut lengths with a fine tooth saw, squarely
  2. File the cut edge smooth and remove the burr, or it will not seat in the union
  3. Clip the gutter into the brackets, back edge first then front
  4. Fit unions, angles and stop ends
  5. Leave the expansion gap indicated by the moulded marks inside each union. This is not optional
  6. Check the seals are seated in the unions before assembling
  7. Work along the run to the outlet

Expansion is real and significant. A long run of plastic gutter fitted hard will buckle in summer heat and pull its joints open in winter.

Step 7: the downpipe

  1. Fit the outlet in the gutter above the intended downpipe position
  2. Where the downpipe must move inward to the wall, use an offset or swan neck: two bends and a short connecting piece
  3. Drop a plumb line from the outlet to establish the vertical
  4. Fix brackets at roughly 1.8m to 2m centres, and always at every joint and at the top and bottom
  5. Drill and plug into the masonry, into a brick rather than a joint where possible
  6. Assemble the pipe into the sockets, again leaving the expansion gap
  7. Fit a shoe at the bottom, directing water into the gully
  8. Check the shoe discharges into the gully, not onto the ground

Step 8: test it

  1. Run a hose into the gutter at the highest point
  2. Watch the water run the full length and down the outlet
  3. Check for standing water
  4. Check every joint for drips
  5. Check the downpipe discharges properly
  6. Check again during the next heavy rain

If it goes wrong

Water stands in the gutter: insufficient fall, or a bracket set too low.

Joints pulling apart in winter: the expansion gap was left too large, or the run is unsupported.

Gutter buckling in summer: no expansion gap left.

Water running behind the gutter: it is set too low, or the felt does not overhang into it.

New gutter does not fit the old fittings: different manufacturer. Match the profile exactly.

A summary

  1. Take an offcut to the merchant; profiles are not interchangeable
  2. Inspect and repair the fascia while the gutter is off
  3. Set the fall with a string line, roughly 3mm per metre
  4. Brackets at 800mm to 1m centres, and each side of every joint
  5. Leave the expansion gap indicated in every union and socket
  6. Test with a hose before you take the ladder down